Computer Room Air Handling Units for Enterprise, Colocation and Hyperscale Data Centers

With your next Computer Room Handling Unit from Data Aire, you will Maximize server space in your data center Minimize low pressure areas Reduce your costs Enable more leasable space Reduce electrical and piping requirements

Maximize server space. Minimize low pressure areas. Reduce costs. Enable more space. Reduce requirements.

28,000

Airflow 28,000 CFM
Water Flow 290 GPM @ 45ºF

32,000

Airflow 32,000 CFM
Water Flow 290 GPM @ 45ºF

40,000

Airflow 40,000 CFM
Water Flow 330 GPM @ 45ºF

46,000

Airflow 46,000 CFM
Water Flow 330 GPM @ 45ºF

52,000

Airflow 52,000 CFM
Water Flow 364 GPM @ 45ºF

60,000

Airflow 60,000 CFM
Water Flow 420 GPM @ 45ºF

gForce Chilled Water System

High Efficiency Cooling for High Density Loads

Data Aire offers computer room air handlers up to 730 kW.

The gForce Computer Room Air Handler (CRAH) is a system often used in data centers to mitigate the heat produced by server racks and other equipment. This CRAH uses fans, cooling coils and chilled water to return cold air to the space.

These standard floor, in-row, ceiling, and wall systems are engineered-to-order for a design that meets your application requirements.

  • Features

    • Maximum operational flexibility
    • Growth potential
    • Greater service access
    • Versatile microprocessor controller
    • Dependable relay autochangeover unit
    • Accessories that help prevent hot spots
    • Less restrictive airflow
    • Highest level of efficiency
    • Radially-discharged air for uniform static pressure across a raised floor
  • Design

    • Front discharge
    • Specially designed tubular steel frame for minimum space requirements
    • Low-watt density finned tubular sheathed elements
    • A-frame coil providing greater efficiency in the cooling and dehumidification process
    • Backward curved plenum fans with EC motors
    • Three-stage reheat (available in select configurations)
    • Upflow or downflow configuration
  • Connect to your BMS | DCIM

    Equipped with dap4 touch for the dap4 control panel. dap4 supports the following network protocols for integration with a BMS.

    • Modbus RTU
    • TCP/IP
    • SNMP V1 or V2,
    • BACnet IP or MS/TP
    • LonTalk SNVT

Continue Exploring Data Aire

Data Center Outlook in a COVID World – Video FastChat

Data center numbers are growing – but is your efficiency falling? The latest AFCOM State of the Data Center report, post-COVID, indicates strong growth in the data center space. This includes cloud, edge, and even colocation space. However,…

Data Center Expansion Through Adaptive Reuse | Executive Roundtable

Adaptive reuse began as a plan to convert classic buildings either for their charm, or to boost the economic preservation of historical buildings. Today, adaptive reuse has a much more pragmatic purpose – enhancing our physical and digital…

When is HVAC Economization a Good Fit?

What’s driving Data Aire to provide more efficient and flexible precision cooling systems to the Data Center market?

How Prefab Modular Data Centers Fell in Love with Thermal Control

They say marriage is a partnership – one built on trust, flexibility and shared goals. If that’s the case, precision cooling manufacturers and prefab data center or power module designers are a perfect match.
DX Cooling HVAC System

DX Cooling – Making the Right Cooling System Selection

When you’re looking to find the best precision cooling equipment for the environmental control infrastructure of your facility, you will quickly find that precision cooling equipment comes in two main categories: direct expansion system (DX)…
Chilled Water Cooling System

Chilled Water Cooling – Is It the Right System for You?

In existing buildings, you may not think you have a choice regarding chilled water (CHW) vs. direct expansion (DX) systems, but read on, what you learn may surprise you. Typically, the decision regarding which cooling source is better for…
Digital Revolution Cloud Data Center

The Data Center Revolution – Are You Ready?

Author: Eric Jensen, VP/GM, Data Aire Sometimes we hear people comment that we should be thankful to live in such interesting times. However, can there be too much of a good thing? For example, in the tech world things are moving so quickly…
Computer Server Room

Data Center Efficiency Gains with Optimized Airflow Solutions

Cooling Techniques and New Approaches to Efficiency There are new and emerging options around CRAC designs, condensers, fluid coolers, advanced system controls, containment solutions, various cooling systems like chilled water or direct expansion,…
Free Cooling - Data Center Economization

Is Free Cooling Really Free?

What is Free Cooling? The concept of ‘free cooling’, or perhaps better put, economization solutions, really deserves some definition. First of all, did you know that free cooling is now virtually mandated by the requirements of ASHRAE 90.1[1]?…